Developer Guide and Reference

  • 2021.2
  • 03/26/2021
  • Public Content

DPCT1075

Message

Migration of cuFFT calls may be incorrect and require review.

Detailed Help

The warning is generated in the following cases:
  1. In the original code one cuFFT handle may be associated with different streams, but the Intel® DPC++ Compatibility Tool could not detect which stream was used by cuFFT calls.
  2. In the migrated code one or more commit calls need to be used, but the Intel® DPC++ Compatibility Tool could not deduce how to generate the correct set of commit calls.
For example:
// Original code: cufftPlan1d(plan, ...); cufftExecR2C(plan, ...); // this call is using default stream cufftSetStream(plan, s2); cufftExecR2C(plan, ...); // this call is using s2 stream
// Migrated code: /* DPCT1075: Migration of cuFFT calls may be incorrect and requires review. */ plan->commit(*s2); // wrong queue is used ... dft::compute_forward (...); ... // missing commit call dft::compute_forward(...);
// Fixed code: plan->commit(dpct::get_default_queue()); // using default queue ... dft::compute_forward (...); ... plan->commit(*s2); // added new commit call with *s2 queue dft::compute_forward(...);

Suggestions to Fix

Check that
oneapi::mkl::dft::descriptor::commit()
calls were generated correctly and are using the correct queue parameter. Fix the code if needed by adding missing commit calls and adjusting queue parameters.

Product and Performance Information

1