Deleting Suppression Rules Applied to Marked Result Data in the GUI

Prerequisite: Marked result data in the GUI from a new suppression rule(s).

To delete a new rule:

  1. In the Code Locations pane, right-click marked result data.
  2. In the context menu, choose Do Not Suppress to display the Delete Suppressions dialog box.
  3. Select a rule to delete.
  4. If desired, click the View... button to view the stack/traceback frame(s) in the rule. When you are finished viewing, close the View Stack dialog box.
  5. Click the Remove button.

Outcome: In the Code Locations and Problems panes, the Intel Inspector unmarks result data accordingly.

For more complete information about compiler optimizations, see our Optimization Notice.