Clock Signal Termination and Conditioning

Signal Name Pullup Voltage

Rmin (Ω)

CLOAD (pF) Trise (ns) Tfall (ns)
CLK_19P2M_LS 1.8 1200 10 16 15

CODEC_MCLK_LS

1.8 1200 10 16 15

PMIC_SLPCLK_1_LS

3.3 1100 47 54 20

 

Example Using CLK_19P2M_LS Signal

The following diagram shows how to use the information in the table to position a pullup resistor for the signal CLK_19P2M_LS. For information about how the values in the table were measured refer to Termination and Conditioning.