stop-after

Automatically stop data collection after a specified length of time (in seconds).

GUI Equivalent

Project Properties > Analysis Target > [Analysis Type] > Advanced > Automatically stop collection after (sec)

Syntax

--stop-after=<integer>

Arguments

<integer> is number of seconds.

Default

No default argument

Actions Modified

collect

Usage

Skip uninteresting parts of your target application and analyze only interesting parts. This is the flip side of starting an application with collection paused.

Usage can decrease analysis overhead.

Example

Run a Survey analysis. Stop data collection after 30 seconds.

$ advixe-cl --collect=survey --project-dir=./myAdvisorProj --stop-after=30 -- ./bin/myTargetApplication

See Also

For more complete information about compiler optimizations, see our Optimization Notice.