CollapseAll image

Admin: Modify Storage Limits

The following steps describe how to modify some of the global storage limits.

1.  Retrieve the instance of AMT_ThirdPartyDataStorageAdministrationService, where the “Name” key equals “Intel(r) AMT Third Party Data Storage Administration Service”.

2.  Invoke AMT_ThirdPartyDataStorageAdministrationService.SetGlobalStorageAttributes to modify the values of the current parameters.  Pass the new values as input parameters:

Parameter

Description/Value

MaxPartnerStorage

Maximum number of bytes that may be used by all partner applications.

MaxNonPartnerTotalAllocationSize

Maximum number of bytes that an individual non-partner application may allocate.

 

Click here for a snippet demonstrating this step

You can execute this snippet by inserting it into the execution template found here.

  

$thirdPartyDataStorageAdministrationServiceRef = $wsmanConnectionObject.NewReference("SELECT * FROM AMT_ThirdPartyDataStorageAdministrationService WHERE Name='Intel(r) AMT Third Party Data Storage Administration Service'")

$inputObject = $thirdPartyDataStorageAdministrationServiceRef.CreateMethodInput("SetGlobalStorageAttributes")

$inputObject.SetProperty("MaxPartnerStorage", "8192")

$inputObject.SetProperty("MaxNonPartnerTotalAllocationSize", "12288")

$outputObject = $thirdPartyDataStorageAdministrationServiceRef.InvokeMethod($inputObject)

$returnValue = $outputObject.GetProperty("ReturnValue")

 

 

Instance Diagram

Not applicable

Classes Used in This Flow

SDK Sample

Located at:<SDK_root>\Windows\Intel_AMT\Samples\WS-Management\StorageAdministration

 

See Also:

   Storage Concepts and Objects

   Application Development Guidelines

   Examples of Using the Storage Feature