The following table describes the CIM elements used to implement the alarm clock feature.
|
Element Name |
Description |
Instance Creation** |
Cardinality |
|
Classes | |||
|
Provides the properties and methods that implement the Intel AMT alarm clock. |
Static |
1 | |
|
(Starting with Release 8.0) Defines the characteristics of an alarm. |
Implicit |
0-6 (includes legacy instance) | |
|
(Starting with Release 8.0) Indicates what caused the last host reboot. The reason is an alarm clock occurrence, a remote control action or another (non-Intel AMT) reason. |
Implicit |
1 | |
|
Associations | |||
|
Associates the service with the Managed System instance of CIM_ComputerSystem. |
Static |
* | |
|
(Starting with Release 8.0) Associates an instance of IPS_AlarmClockOccurrence with AMT_AlarmClockService |
Implicit |
0-6 (includes legacy instance) | |
|
* Multiple instances ** Instance Creation: • Implicit: Instances created implicitly by Intel AMT in response to a user CIM operation • Static: Instances created by Intel AMT on initialization • User: The class supports create/delete | |||

|
Copyright © 2006-2022, Intel Corporation. All rights reserved. |