Compatibility
This event is supported by Intel AMT Release 2.0 and later releases. Starting with Release 7.0, this event is no longer supported. Instead, Intel AMT will send a CPU Dead On Arrival Event.
Trap Definition
Specific Trap Info | |
Event Sensor Type |
07h (Processor) |
Event Type |
01h (Generic) |
Event Offset |
04h (FRB3/Processor Startup/Initialization failure (CPU didn’t start)) |
Variable Binding Info | |
Event Source Type |
68h (ASF1.0 Implementation) |
Event Severity |
10h (Critical) |
Sensor Device |
FFh (NS) |
Sensor Number |
FFh (NS) |
Entity |
09h (Processor module) |
Entity Instance |
60h (for instance #0), 61h (for instance #1), … |
EventData[1...8] |
{00, 00, 00, 00, 00} |
Remarks
This Event is sent to all Event subscribers regardless of
any Event Filter state.
This Event is logged regardless of any Event Filter
state.
Copyright © 2006-2022, Intel Corporation. All rights reserved. |