CPU Missing Event

Compatibility

This event is supported by Intel AMT Release 2.0 and later releases. Starting with Release 7.0, this event is no longer supported. Instead, Intel AMT will send a CPU Dead On Arrival Event.

Trap Definition

Specific Trap Info

Event Sensor Type

07h (Processor)

Event Type

01h (Generic)

Event Offset

04h (FRB3/Processor Startup/Initialization failure (CPU didn’t start))

Variable Binding Info

Event Source Type

68h (ASF1.0 Implementation)

Event Severity

10h (Critical)

Sensor Device

FFh (NS)

Sensor Number

FFh (NS)

Entity

09h (Processor module)

Entity Instance

60h (for instance #0), 61h (for instance #1), …

EventData[1...8]

{00, 00, 00, 00, 00}

Remarks

This Event is sent to all Event subscribers regardless of any Event Filter state.
This Event is logged regardless of any Event Filter state.