Description of PT_STATUS Responses

Code

Description

PT_STATUS_APPLICATION_DOES_NOT_EXIST

The application handle provided in the request message is not valid.

PT_STATUS_AUDIT_FAIL

The command is defined in Audit Log policy as a critical event and cannot be logged.

PT_STATUS_BLOCK_DOES_NOT_EXIST

The specified block does not exist.

PT_STATUS_BLOCK_LOCKED_BY_OTHER

The specified block is locked by another application.

PT_STATUS_BLOCK_NOT_LOCKED

The specified block is not locked.

PT_STATUS_BLOCKING_COMPONENT

One of the ME components is not ready .

PT_STATUS_CERT_KEY_NOT_MATCH

Key pair does not match.

PT_STATUS_DATA_MISSING

Essential data is missing on CommitChanges() command.

PT_STATUS_DUPLICATE

The parameter specified is a duplicate of an existing value.

PT_STATUS_EVENTLOG_FROZEN

Event log is frozen.

PT_STATUS_FLASH_WRITE_LIMIT_EXCEEDED

The operation failed because the flash wear-out protection mechanism prevented a write to an NVRAM sector.

PT_STATUS_GROUP_DOES_NOT_EXIST

The specified group does not exist.

PT_STATUS_INTERNAL_ERROR

An internal error occurred while performing the operation.

PT_STATUS_INVALID_AUTH_TYPE

Specified Key algorithm is invalid.

PT_STATUS_INVALID_BYTE_COUNT

The specified byte count is invalid.

PT_STATUS_INVALID_BYTE_OFFSET

The specified byte offset is invalid.

PT_STATUS_INVALID_CERT

Invalid X.509 Certificate or invalid certificate handle.

PT_STATUS_INVALID_COMMAND

The command specified in the remote control command is not supported by the Intel AMT device.

PT_STATUS_INVALID_CREDENTIALS

Invalid User credentials.

PT_STATUS_INVALID_DHCP_MODE

Specified DHCP mode is invalid.

PT_STATUS_INVALID_DOMAIN_NAME

Specified Domain name is invalid.

PT_STATUS_INVALID_GROUP_PERMISSIONS

The specified group permission bits are invalid.

PT_STATUS_INVALID_HANDLE

The handle specified in the command is invalid.

PT_STATUS_INVALID_INDEX

Specified index is not valid.

PT_STATUS_INVALID_IP_ADDRESS

Specified IP address is invalid.

PT_STATUS_INVALID_KEY

Invalid RSA Key.

PT_STATUS_INVALID_MEMBER_COUNT

The specified member count is invalid.

PT_STATUS_INVALID_NAME

Specified name is invalid.

PT_STATUS_INVALID_NETMASK

An invalid netmask was supplied (a valid netmask is an IP address in which all ‘1’s are before the ‘0’ – e.g. FFFC0000h is valid, FF0C0000h is invalid).

PT_STATUS_INVALID_PARAMETER

Invalid input parameter.

PT_STATUS_INVALID_PASSPHRASE

Passphrase is invalid.

PT_STATUS_INVALID_PASSWORD

The password specified in the User ACL is invalid.

PT_STATUS_INVALID_PRIORITY

Priority setting is invalid.

PT_STATUS_INVALID_PROVISIONING_STATE

Specified provisioning state is not valid.

PT_STATUS_INVALID_PT_MODE

Specified mode of operation is invalid.

PT_STATUS_INVALID_REALM

The realm specified in the User ACL is invalid.

PT_STATUS_INVALID_REGISTRATION_DATA

1. Either an invalid name was entered or an “Enterprise” name was specified that was not pre-registered. 2. The current registration was attempted from an interface different from the one used for the initial registration of the application.

PT_STATUS_INVALID_SPECIAL_COMMAND

The special command specified in the remote control command is not supported by the Intel AMT device.

PT_STATUS_INVALID_TIME

Specified time is not valid.

PT_STATUS_MAX_KERB_DOMAIN_REACHED

The FW allows storing an SID from a limited number of domains. This SID domain does not exist and there is no space to store a new domain.

PT_STATUS_MAX_LIMIT_REACHED

No available storage in the specified structure.

PT_STATUS_NO_ASSOCIATION

Current functionality requires association to a Key Pair.

PT_STATUS_NOT_ENOUGH_STORAGE

The number of bytes requested cannot be allocated in ISV storage.

PT_STATUS_NOT_FOUND

Unable to find specified element.

PT_STATUS_NOT_OWNER

The requesting application is not the owner of the block as required for the requested operation.

PT_STATUS_NOT_PERMITTED

The requesting application is not permitted to request execution of the specified operation.

PT_STATUS_OPERATION_IN_PROGRESS

Operation is not complete. This can occur when the Intel ME needs to generate a key pair (for example, when performing a full unprovision). Wait and then retry.

PT_STATUS_PKI_GENERATING_KEYS

Reserved for future use.

PT_STATUS_PKI_MISSING_KEYS

Reserved for future use.

PT_STATUS_REQUEST_UNEXPECTED

The requested operation cannot be performed because a prerequisite request message has not been received.

PT_STATUS_STORAGE_ACL_ENTRY_IN_USE

The FPACL or EACL entry is used by an active registration and cannot be removed or modified.

PT_STATUS_SUCCESS

Operation completed successfully.

PT_STATUS_UNSUPPORTED

Setting is not supported by this product.

PT_STATUS_UNSUPPORTED_BOOT_OPTION

The boot option specified in the remote control command is not supported by the Intel AMT device.

PT_STATUS_UNSUPPORTED_OEM_NUMBER

The OEM number specified in the remote control command is not supported by the Intel AMT device.

PT_STATUS_USER_CONSENT_REQUIRED

User consent is required for this operation but was not received.

 