Redirection Manager Events

The following table describes the Redirection Manager events (App ID = 18). Beginning in Release 8.0, all Redirection Manager events are enabled by default.

Event Name

ID

Description

Parameters

Trigger

IDE-R Session Opened

0

An application opened a Storage Redirection session

Note: From Release 12.0 onward, this event is flagged as super_critical

None

Storage Redirection session is authenticated

IDE-R Session Closed

1

An application or the firmware closed an Storage Redirection session. Note that this event is always recorded in the log as if it was initiated locally.

Note: This event cannot be flagged as critical.

None

Storage Redirection session receives end of session message.

Network connection failed.

Internal FW decision (e.g., timeout). A FW reset will close the session, but session closed will not be logged.

IDE-R Enabled

2

Storage Redirection was enabled

None

WS-MAN: AMT_RedirectionService.RequestStateChange

MEBx: Enable IDE-R

IDE-R Disabled

3

Storage Redirection was disabled

None

WS-MAN: AMT_RedirectionService.RequestStateChange

MEBx: Disable IDE-R

SoL Session Opened

4

SOL session was opened by an application

Note: From Release 12.0 onward, this event is flagged as super_critical

None

SOL session is authenticated.

SoL Session Closed

5

SOL session was closed by an application or by firmware. Note that this event is always recorded in the log as if it was initiated locally.

Note: This event cannot be flagged as critical.

None

SOL session receives end of session message.

Network connection failed.

Internal FW decision (e.g., timeout). A FW reset will close the session, but session closed will not be logged.

SoL Enabled

6

SOL was enabled

None

WS-MAN: AMT_RedirectionService.RequestStateChange

MEBx: Enable SOL

SoL Disabled

7

SOL was disabled

None

WS-MAN: AMT_RedirectionService.RequestStateChange

MEBx: Disable SOL

KVM Session Started
(Release 6.0 and later releases)

8

KVM session was established

Note: From Release 12.0 onward, this event is flagged as super_critical

None

Remote KVM viewer established a KVM session - authenticated

KVM Session ended
(Release 6.0 and later releases)

9

KVM session was terminated

Note: This event cannot be flagged as critical.

None

WS-MAN: IPS_KVMRedirectionSettingData.TerminateSession

KVM session closed by viewer

Network connection failed

KVM enabled
(Release 6.0 and later releases)

10

KVM was enabled (either locally or remotely)

None

WS-MAN: CIM_KVMRedirectionSAP.RequestStateChange

MEBx: Enable KVM

KVM disabled
(Release 6.0 and later releases)

11

KVM was disabled (either locally or remotely)

None

WS-MAN: CIM_KVMRedirectionSAP.RequestStateChange

MEBx: Disable KVM

VNC password failed3 times
(Release 6.0 and later releases)

12

An RFB password that did not match was inserted three times
End of Support Note: Port 5900 is no longer supported. Attempting to configure an RFB password or enabling the port via IPS_KVMRedirectionSettingData.PUT causes Intel AMT to return the message unsupported. For details on affected releases, see Working with Port 5900.

None

Three consecutive RFB password authentication failures

Copyright © 2006-2022, Intel Corporation. All rights reserved.