Remote Control Events

The following table  describes the Remote Control events (App ID = 17). Beginning in Release 8.0, all Remote Control events are enabled by default.

Event Name

ID

Description

Parameters

Trigger

Performed Power-Up

0

Remote power up initiated

UINT8 BootOptions[7] (consisting of four parameters of format SpecialCommandType, SpecialCommandParameterType, BootOptionsType, and OemParametersType)

WS-MAN: CIM_PowerManagementService.RequestPowerStateChange

Web UI: remote control page,

Performed Power-Down

1

Remote Power down initiated

None

WS-MAN: CIM_PowerManagementService.RequestPowerStateChange

Web UI: remote control page,

Performed Power-Cycle

2

Remote Power Cycle initiated

UINT8 BootOptions[7]

WS-MAN: CIM_PowerManagementService.RequestPowerStateChange

Web UI: remote control page,

Performed Reset

3

Remote reset initiated

UINT8 BootOptions[7]

WS-MAN: CIM_PowerManagementService.RequestPowerStateChange

Web UI: remote control page

Set Boot Options

4

Boot Options set

Note: From Release 12.0 onward, this event is flagged as super_critical

UINT8 BootOptions[7]

WS-MAN:

CIM_BootService.SetBootConfigRole

CIM_BootConfigSetting().ChangeBootOrder

The following method will add a record to the log if it is applied on the next boot option:

AMT_BootSettingData.Put

Performed Graceful Power down

5

Remote graceful power down initiated

Added in Release 9.0

None

SOAP: n/a

WS-MAN:

CIM_PowerManagementService.RequestPowerStateChange

Web UI: remote control page

Performed Graceful Power reset

6

Remote graceful reset initiated

Added in Release 9.0

UINT8 BootOptions[7]

SOAP: n/a

WS-MAN:

CIM_PowerManagementService.RequestPowerStateChange

Web UI: n/a

Performed Standby

7

Remote Standby initiated

Added in Release 9.0

None

SOAP: n/a

WS-MAN:

CIM_PowerManagementService.RequestPowerStateChange

Web UI: n/a

Performed Hiberate

8

Remote Hiberate initiated

Added in Release 9.0

None

SOAP: n/a

WS-MAN:

CIM_PowerManagementService.RequestPowerStateChange

Web UI: n/a

Performed NMI

9

Remote NMI initiated

Added in Release 9.0

None

SOAP: n/a

WS-MAN:

CIM_PowerManagementService.RequestPowerStateChange

Web UI: n/a