Compatibility
This event is supported by Intel AMT Release 2.5 and later releases.
Trap Definition
Specific Trap Info | |
Event Sensor Type |
C0h (OEM Reserved – User Notification) |
Event Type |
70h (OEM Discrete – User notification) |
Event Offset |
00h |
Variable Binding Info | |
Event Source Type |
58h (System MNG card) |
Event Severity |
02h (Information) |
Sensor Device |
FFh (NS) |
Sensor Number |
FFh (NS) |
Entity |
26h (Mgmt Device) |
Entity Instance |
61h (port #1 (LAN port)) or |
EventData |
AAh (EventData 2-5 valid), |
Event Data Report State Details
#Byte |
Name |
Bits |
Description |
0 (EventData 2) |
Version |
0-3 |
Must be zero |
0 (EventData 2) |
Reason |
4-7 |
0h – General Notification |
1-3 (EventData 3-5) |
Reason Info |
|
Data formatted according to Reason code |
Reason Info Details
Reason |
#Byte |
Name |
Bits |
Description |
General notification |
1 |
Notification Code |
0-7 |
Reserved |
2 |
Reserved |
0-7 |
Reserved | |
3 |
Reserved |
0-7 |
Reserved | |
Circuit Breaker notification |
1 |
Notification Code |
0-7 |
0h – CB Drop Tx filter hit |
2 |
Reserved |
0-7 |
Reserved | |
3 |
Reserved |
0-7 |
Reserved | |
EAC notification |
1 |
Notification Code |
0-7 |
Reserved |
2 |
Reserved |
0-7 |
Reserved | |
3 |
Reserved |
0-7 |
Reserved | |
Remote diagnostics |
1 |
Notification Code |
0-7 |
0h – Remote Redirection session started (SOL) |
2 |
Reserved |
0-7 |
Reserved | |
3 |
Reserved |
0-7 |
Reserved | |
WLAN notification |
1 |
Notification Code |
0-7 |
2h – Host profile mismatch. Management Interface
ignored. |
2 |
Reserved |
0-7 |
Reserved | |
3 |
Reserved |
0-7 |
Reserved |
Remarks
A local service that wishes to receive a user notification alert should subscribe for an alert with a PolicyID field equal to 0x86.
Copyright © 2006-2022, Intel Corporation. All rights reserved. |